EasySeal™ Satin & Gloss
How-to-Guide

Preliminary Testing
Before using the product for your entire project, try it out on a small, hidden area of the surface you'll be working on. This will let you see how it looks and if it's the right fit for your project.
1 . Pre-Application
Step 1 - Clean & Dry : EasySeal™ should be applied to a surface that is completely clean and dry. If the surface was cleaned with water or pressure washed, allow it to dry for at least 24 hours before sealing. Ensure the surface is free from dust, dirt, oil, grease, paints, glues, non-solvent-based acrylic sealers, curing agents, efflorescence, chemical contaminants, rust, algae, mildew, and other materials that might prevent proper bonding.
Step 2 -Cured: The concrete or overlay must be fully cured before application. It is recommended that cement-based products cure for at least 28 days to achieve optimal results.
Step 3 - Temperature: For optimal results, apply EasySeal™ in temperatures ranging from 40°F (4°C) to 95°F (35°C).
Application should ideally occur in the early evening when air and surface temperatures are cooling, and the sun is no longer directly overhead. To prevent bubbling and hazing, avoid application during the morning or midday.
Step 4 - Sound: Apply only to cement-based products that are not flaking or spalling. The substrate must be structurally sound. For surfaces showing signs of delamination, employ diamond grinding, shot blasting, or similar mechanical methods for removal.
Step 5 - Profiled: Perform an absorption test to check if the concrete is ready for staining. Pour water onto the concrete surface and wait for 3-5 minutes.
If the water is not absorbed, the surface will need to be cleaned and etched with CitrusEtch™ to open the pores of the concrete. Detailed instructions can be found in the CitrusEtch™ Technical Data Sheet.
Note: Poorly finished, broomed, or very old surfaces may absorb ColorWave® more deeply, leading to less visiblecolor.
Before
After
IMPORTANT: Use spiked shoes when etching. If shoe prints are etched onto the concrete surface, you will need to usea mechanical grinder to removethem.
Required Tools
Personal Safety: Always wear appropriate personal protective equipment as recommended in the Safety Data Sheet.
2 . Preparation
- When applying, be aware that odors can be strong. Ensure the area is properly ventilated during application to maintain a safe and comfortable working environment.
- Plan the work area in manageable sections, utilizing natural break points such as walls and joints to avoid discrepancies in application. Maintain control of wet edges to reduce overlap marks.
- Area Preparation: Protect surfaces not intended for sealing by covering surrounding areas to prevent accidental application.
- Avoid using tape on concrete surfaces before or after sealing, as adhesives and plasticizers can interfere with thestain's effectiveness.
3 . Application
Solvent Control: Block HVAC ducts to prevent solvent spread and odors. Ensure all ignition sources, like pilot lights, are extinguished before starting.
Applying with pump sprayer
- Apply EasySeal™ in circular motions to ensure even coverage. It is important to apply thin layers to avoid puddling and ensure uniform drying.
- Start and stop spraying into a bucket or off the work area to prevent drips. Back roll afterwards to smooth out any puddles or overlaps, maintaining a thin, even layer.
- If you need to walk on the sealed area, use spiked shoes to avoid disturbing the wet sealer and maintain a smooth application.
Applying with roller
- Use a ⅜” nap roller with a solvent-resistant core. Allow the roller's weight to apply the product without adding extra pressure, which could cause streaks and uneven coverage. Focus on applying thin, consistent layers.
- Before adding more product to the paint tray, shake the bottle for even consistency.
4 . Drying & Recoating
- Dry Time Between Coats: Wait 6 to 12 hours, depending on environmental conditions.
- Testing Dryness: To check if the surface is ready for the next coat, press it with a thumbnail. If the surface doesn't dent or scratch, it is sufficiently dry for recoating.
- Coat Application: Ensure the first coat is thoroughly dry before applying a second thin coat. The emphasis on thin coats is crucial for achieving the best finish and performance.
- Recommended Coats: Two thin coats are advised for best performance and durability.
- Application Caution: To prevent bubbling, hazing, and other imperfections, it is essential to apply the product in thin coats rather than heavy applications.
- Foot Traffic: Keep the area free from foot traffic for at least 24 hours to allow the topcoat to properly set.
- Vehicle Traffic: Avoid vehicle traffic for 48-72 hours to ensure the sealer fully cures and offers maximum protection.
For Indoor Projects
- To enhance durability and extend the life of the sealer protecting the stain, consider applying an additional coat of ProWax Polish™ after thesealer has fully cured.
Additional Information
Coverage
Coverage
Estimated coverage is approximately 200 square feet (18.58 m²) per gallon. Actual coverage rates may diff er based on factors such as surface porosity, texture, the age and condition of the concrete, chosen application method, and prevailing environmental conditions.
Surface Protection and Maintenance
Surface Protection and Maintenance
FOR EXTERIOR SURFACES:
● Regularly inspect sealed areas for signs of thinning or wear due to foot or vehicular traffic. Reapply the sealer as needed to maintain protection and appearance.
FOR INTERIOR SURFACES:
● Regularly examine surfaces coated with ProWax Polish™ for wear or thinning, especially in high-traffic areas. Reapply the coating as necessary to preserve the surface's integrity and aesthetics.
Suitability Sample
Suitability Sample
Prior to application, prepare a sufficient number of test areas on the actual substrate to determine the aesthetic suitability of the product for its intended use.
Limitation & Precautions
Limitation & Precautions
- Batch Variability: The supply of specialized pigments may vary between batches. To ensure color consistency, use the same batch for the entire job or mix multiple batches together ("boxing").
- Surface Compatibility: EasySeal™ may experience adhesion challenges when applied to hard-troweled (machine-smoothed) surfaces or surfaces whose pores are smaller than the sealer's particles. This can result in the sealer drying without proper adhesion.
- Avoid Liquid Contact During Curing: Prevent any liquids, including sweat, from coming into contact with the uncured coating, as this can affect both the curing process and the quality of the finish.
DANGER: VAPOR HARMFUL, HARMFUL OR FATAL IF SWALLOWED. FLAMMABLE. EYE & SKIN IRRITANT. Do not swallow. Do not breathe fumes. Do not use near heat, sparks or flames. Do not smoke. Do not get in eyes. Do not get on skin or clothing. KEEP OUT OF REACH OF CHILDREN. Wear a mask. Wear safety glasses and chemical resistant gloves. Use only in a well-ventilated area. Contains: Xylene, Petroleum distillates, Trimethylbenzene and Ethylbenzene FIRST AID TREATMENT: If swallowed, call physician immediately. Do not induce vomiting. If in eyes, rinse with water for 15 minutes. If on skin, rinse well with water. If breathed in, move person into fresh air. WARNING: This product can expose you to chemicals including Ethylbenzene and Isopropylbenzene which are known to the State of California to cause cancer, and Toluene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Slip Resistance
Slip Resistance
● EasySeal™ Gloss can be more slippery.
For enhanced slip resistance on exterior surfaces, integrate OxiGrip™ into the sealer. Ensure you obtain and review the appropriate Technical Data Sheet and Safety Data Sheet prior to using this product.
Disposal
Disposal
For the disposal of any unused product, please refer to your local environmental or hazardous waste management authority to ensure compliance with local regulations.
Shelf Life & Storage
Shelf Life & Storage
EasySeal™ should be used within one year of purchase for optimal effectiveness. For storage, keep the product indoors, in a cool area away from direct sunlight and heat sources.
Available Sizes & Packaging
Available Sizes & Packaging
- 4-Ounce(0.118L) Bottle
- 1-Gallon (3.785L) Jug
- 5-Gallon (18.925L) Carboy
Clean-Up
Clean-Up
For cleaning tools and equipment after using EasySeal™, use Xylene.
Complementary Products
Complementary Products
● ProClean Degreaser™ Concentrate Cleaning agent.
● CitrusEtch™ - Concrete etching agent.
● ProClean Neutralizer™ Concentrate.
● OxiGrip™ Slip resistant Sealer additive.
● ProWax Polish™ Premium Floor Wax.